BSCs are open workspaces designed to protect laboratory personnelthrough the use of directional air flow and High Efficiency Particulate Air filters.

Key considerations for selecting appropriate PPE include

  • Characteristics of the biological agent
  • Type of work being carried out
  • Availability of national regulations
  • All of the above are correct

Essential biosafety equipment do not include

  • PPE
  • Autoclave
  • Bench
  • Biological safety cabinet

HEPA filter performance of a minimum efficiency of 99.97% should be used

Things to avoid when using a BSC

  • Use open flame
  • Rapid arm movements
  • Block the grills
  • All of the above mentioned

Which of the following description of the autoclave is incorrect?

  • Do not overload the autoclave
  • Use separate autoclaves for ‘clean’ and ‘dirty’ loads
  • No need to monitor autoclave sterization regularly
  • Do not operate overnight

Different types of glove may be needed for different tasks or with other occupational hazards, such as heat or sharps.

Air particles are caught by HEPA through which mechanism?

  • Diffusion
  • Interception
  • Impaction
  • All of the above are correct

PPE is used only in BSL-2,3 and 4 biological laboratories

Gloves should always be inspected before use to check that they are intact.

When use combinations of PPE needs to consider complementing one another

Which description is incorrect?

  • Minimum distance between BSC and door is 1.1 m
  • Minimum distance between 2 side-by-side BSCs is 1 m
  • 2 BSCs put in the opposite site along the wall, the minimum space between 2 persons is 3.1 meters
  • The airflow curtain that helps provide protection when working in a BSC is fragile

Work surfaces and interior walls need to be disinfected only after each use

The minimum space between BSC and door is 1.1 meter and the same distance between 2 side-by side BSCs.

Which level of biosafety laboratory required to use PPE?

  • BSL-1
  • BSL-2
  • BSL-3
  • All of the above are correct

Autoclave sterilization condiction?

  • 121°C for 60 minutes
  • 100°C for 60 minutes
  • 85°C for 60 minutes
  • 121°C for 15 minutes

If an autoclave used for sterilize the infectious substances, Its exhaust should be filtered through a filter with membrane size of

  • 0.1 micron
  • 0.2 micron
  • 0.3 micron
  • 0.4 micron

Autoclaving is the most dependable method of sterilizing laboratory equipment and decontaminating biohazard wastes.

Which form of PPE is one of the most critical and easily implemented ?

  • Footware
  • Eye protection
  • Lab coat
  • Respiratory protection

After moving a BSC within the laboratory, it is not nessersary to certified the BSC.

Which class of BSC can not protect ptoducts?

  • Class III
  • Class I
  • Class II A1
  • Class II B1

When infectious materials are sterilized, exhaust of an autoclave should be filtered through a filter with 0.2 micron membrane

Which class of BSC do not have HEPA filtered supply air?

  • Class II
  • ClassIII
  • Class I
  • Class II B1

The proper type of PPE must be chosen and personnel must be trained in its proper use and know how to detect any faults

Which one is not a key consideration for selecting PPE?

  • Volumes and concentrations of the biological agent
  • Color
  • Other PPE being worn
  • Individual needs of the laboratory personnel

Which of the following descriptions of the functions of a biological safety cabinet is incorrect?

  • Air in the Class I, Class II B2, and Class III BSC is 100% exhausted
  • There are 3 classes of BSC
  • None of BSC can be applied to handle volatile toxic chemicals
  • Class II A1 and A2 BSCs can be a thimble connected

The laboratory director should ensure that the adequate equipment is provided and used properly.

Which PPE is not a core requirement?

  • Respiratory protection
  • Gloves
  • Lab coat
  • Footware

All classes of BSC can protect personnel, enviroment and product