General waste includes industrial waste.

The first step of lab waste management program is to reduce the amount of waste generated.

In facilities where multiple types of biomedical waste are generated, color-coded waste holding bags or containers can be used to differentiate between types of waste

Standard Operating Procedure for Biomedical Waste Management do not include

  • Validation of laboratory
  • Classification of the infectious waste
  • Segregation
  • Decontamination methods

Sterilization using autoclaves should use Bacillus subtilis spores for testing.

Which of the following descriptions of storage condition at waste generating settinfs is incorrect?

  • A maximum of one day at a temperature above 5°C
  • A maximum of three day at a temperature above 5°C
  • refrigerate infectious waste for a maximum of seven days at a temperature below 5°C and above 0°C
  • freeze infectious waste for a maximum of 30 days at a temperature below 0°C

Which one is not biomedical and infectious waste?

  • Infectious waste
  • General office waste
  • Waste sharp implements
  • Cytotoxic waste

Which information do not have to be included on the outermost layer of a waste bag ?

  • The name of the waste
  • The name of the person who generated the waste
  • Weight of the waste
  • Storage temperature of infectious waste

How many categories of “waste”?

  • 1
  • 2
  • 3
  • 4

Waste sharp implements should be storedWaste sharp implements can be storedseparately from other waste

Which of the following descriptions of “waste” is incorrect?

  • Original purpose is unclear
  • Not deliberately created
  • Has economic or market value
  • Any movable solid or liquid substances or objects discarded

Which of the following descriptions of “biomedical and infectious waste” is incorrect?

  • Hazardous industrial waste
  • Substances listed as regulated hazardous industrial waste
  • Decominated before disposal
  • All of the above are incorrect

Waste generating settings may store infectious waste for a maximum of 3 day at a temperature above 5°C.

Use designated autoclaves for sterilizing infectious waste, which are used only to sterilize waste and should not be reused to sterilize equipment.

Industrial waste is divided into “general industrial waste” and “hazardous industrial waste.

Waste management is an integral component of a biosafety program, and comprises

  • Policies
  • Plans
  • Procedures
  • All of the above are correct

Biomedical and infectious waste is one of the substances listed as regulated hazardous industrial waste

Disposal settings may not store infectious waste at a temperature above 5°C

Which information should be included in the signs on specified packaging materials or containers for cytotoxic waste?

  • Name of the waste-producing setting
  • Storage date
  • Quantity and composition
  • All of the above are needed

Each time the sterilizer is used, an operating record must be filled out, an efficiency test must be performed, and the results recorded.

The name of the waste and the name of the person who generated the waste have to included on the outermost layer of the waste bag.

Biosafety can

  • Reduce risk to human/animal health and safety
  • Protect the environment
  • Protect the biological materials
  • All of the above are correct

Removal settings may store infectious waste.

Which description of loading an autoclave is incorrect?

  • Do not overload
  • Total waste volume should not exceed 90%
  • Should also be space between each waste package
  • Need a clearance of 7.6 cm (3 inches) from the top of the container

Waste sharp implements can be stored in a tightly sealed, sturdy container for up to two year

“Sterilization” refers to treatment methods involving only the use of physical principles to sterilize microbes in industrial waste within a certain amount of time

During the sterilization process, the packaging material do not have be resistant to

  • High noise
  • Damp heat
  • High temperature
  • High pressure

Which description of efficency tests of autoclaves is incorrect?

  • Use chemical indicator to check temperature
  • Use chemical indicator for each run
  • Bacillus stearothermophilus spore can be used for any types of sterization
  • Use biological indicator to check efficacy of sterilization

Which one is not a category of infectious waste?

  • Microbial cultures, strains and related bio-produced waste
  • surgical and autopsy waste
  • Carcinogen cytotoxic or other drugs
  • Laboratory waste

Syringes, scalpels, microslides, cover slides, or fractured glass containers are

  • Infectious waste
  • Waste sharp implements
  • Cytotoxic waste
  • General waste